Two-phase pressure drops in a helically coiled steam generator

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

An experimental investigation regarding two-phase diabatic pressure drops inside a helically coiled heat exchanger have been carried out at SIET thermo-hydraulics labs in Piacenza (Italy). The experimental campaign is part of a wide program of study of the IRIS innovative reactor steam generator. The test section consists of an AISI 316 stainless steel tube, 32 m length, 12.53 mm inner diameter, curved in helical shape with a bend radius of 0.5 m and a helix pitch of 0.8 m, resulting in a total height of the steam generator tube of 8 m. The explored operating conditions for two-phase flow experiences range from 192 to 824 kg/m2 s for the mass flux, from 0 to 1 for the quality, from 1.1 to 6.3 MPa for the pressure, from 50 to 200 kW/m2 for the heat fluxes. A frictional two-phase pressure drops correlation, based on an energy balance of the two-phase mixture and including the 940 experimental points, is proposed. Comparison with existing correlations shows the difficulty in predicting two-phase pressure drops in helical coil steam generators.