Published in

Elsevier, Sensors and Actuators A: Physical, (220), p. 204-212, 2014

DOI: 10.1016/j.sna.2014.09.031

Links

Tools

Export citation

Search in Google Scholar

Nanostructured functional Ti-Ag electrodes for large deformation sensor applications

Journal article published in 2014 by A. Ferreira ORCID, C. Lopes ORCID, N. Martin ORCID, S. Lanceros-M??ndez, F. Vaz ORCID
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

This paper reports on the development of thin film-based stretchable electrodes, suitable for different types of sensors. Columnar Ti???Ag thin films with a Ag content of 8 at.% were prepared by D.C. magnetron sputtering on carbon nanotube/poly(vinylidene fluoride) CNT/PVDF piezoresistive composites. GLancing Angle Deposition, GLAD, technique was used to change the typical normal columnar growth microstructure obtained by conventional sputtering, into different growing architectures, such as inclined columns and zigzag profiles, in order to tune mechanical and electrical responses of the materials. Three different incident angles of the particle flux, ?? = 40??, 60?? and 80??, were used to deposit Ti???Ag thin films with the different architectures. Upon uniaxial stretching of the prepared zigzag thin films, the resistance of the thin film starts increasing smoothly for strains up to 3%. Above 10% strain, a sharp increase of the electrical resistance is observed due to film mechanical failure and therefore interruption of the electrical conductivity pathways. Furthermore, the influence of the thin film architecture was also studied with respect to the performance of piezoresistive sensors based on carbon nanotube/poly(vinylidene fluoride), CNT/PVDF, composites in which Ti???Ag coated films served as electrodes for signal acquisition. Electromechanical tests were thus performed in composites with CNT contents close to the percolation threshold, where the electromechanical response, characterized by the Gauge Factor, is the largest. The stability of the piezoresistive response was analyzed for the various architectures of the GLAD sputtered Ti???Ag electrodes, including incident angle and number of zigzag periods. It is shown that thin film architecture has a pronounced influence in the overall sensor response, where the best results are obtained for piezoresistive polymer composites coated with Ti???Ag films, produced with intermediate (?? = 60??) incident angles.