Published in

Springer, European Radiology, 2024

DOI: 10.1007/s00330-024-10693-9

Links

Tools

Export citation

Search in Google Scholar

Enhancing gadoxetic acid–enhanced liver MRI: a synergistic approach with deep learning CAIPIRINHA-VIBE and optimized fat suppression techniques

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract Objective To investigate whether a deep learning (DL) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE) technique can improve image quality, lesion conspicuity, and lesion detection compared to a standard CAIPIRINHA-VIBE technique in gadoxetic acid–enhanced liver MRI. Methods This retrospective single-center study included 168 patients who underwent gadoxetic acid–enhanced liver MRI at 3 T using both standard CAIPIRINHA-VIBE and DL CAIPIRINHA-VIBE techniques on pre-contrast and hepatobiliary phase (HBP) images. Additionally, high-resolution (HR) DL CAIPIRINHA-VIBE was obtained with 1-mm slice thickness on the HBP. Three abdominal radiologists independently assessed the image quality and lesion conspicuity of pre-contrast and HBP images. Statistical analyses involved the Wilcoxon signed-rank test for image quality assessment and the generalized estimation equation for lesion conspicuity and detection evaluation. Results DL and HR-DL CAIPIRINHA-VIBE demonstrated significantly improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE (p < 0.001), with a shorter acquisition time (DL vs standard, 11 s vs 17 s). However, the former presented a more synthetic appearance (both p < 0.05). HR-DL CAIPIRINHA-VIBE showed superior lesion conspicuity to standard and DL CAIPIRINHA-VIBE on HBP images (p < 0.001). Moreover, HR-DL CAIPIRINHA-VIBE exhibited a significantly higher detection rate of small (< 2 cm) solid focal liver lesions (FLLs) on HBP images compared to standard CAIPIRINHA-VIBE (92.5% vs 87.4%; odds ratio = 1.83; p = 0.036). Conclusion DL and HR-DL CAIPIRINHA-VIBE achieved superior image quality compared to standard CAIPIRINHA-VIBE. Additionally, HR-DL CAIPIRINHA-VIBE improved the lesion conspicuity and detection of small solid FLLs. DL and HR-DL CAIPIRINHA-VIBE hold the potential clinical utility for gadoxetic acid–enhanced liver MRI. Clinical relevance statement DL and HR-DL CAIPIRINHA-VIBE hold promise as potential alternatives to standard CAIPIRINHA-VIBE in routine clinical liver MRI, improving the image quality and lesion conspicuity, enhancing the detection of small (< 2 cm) solid focal liver lesions, and reducing the acquisition time. Key Points • DL and HR-DL CAIPIRINHA-VIBE demonstrated improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE, in addition to a shorter acquisition time. • DL and HR-DL CAIPIRINHA-VIBE yielded a more synthetic appearance than standard CAIPIRINHA-VIBE. • HR-DL CAIPIRINHA-VIBE showed improved lesion conspicuity than standard CAIPIRINHA-VIBE on HBP images, with a higher detection of small (< 2 cm) solid focal liver lesions.