Dissemin is shutting down on January 1st, 2025

Published in

Wiley, Catheterization and Cardiovascular Interventions, 6(103), p. 863-872, 2024

DOI: 10.1002/ccd.31019

Links

Tools

Export citation

Search in Google Scholar

Retrograde chronic total occlusion percutaneous coronary intervention via ipsilateral collaterals

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

AbstractBackgroundThere is limited data on retrograde chronic total occlusion (CTO) percutaneous coronary intervention (PCI) via ipsilateral epicardial collaterals (IEC).AimsTo compare the clinical and angiographic characteristics, and outcomes of retrograde CTO PCI via IEC versus other collaterals in a large multicenter registry.MethodsObservational cohort study from the Prospective Global registry for the study of Chronic Total Occlusion Intervention (PROGRESS‐CTO).ResultsOf 4466 retrograde cases performed between 2012 and 2023, crossing through IEC was attempted in 191 (4.3%) cases with 50% wiring success. The most common target vessel in the IEC group was the left circumflex (50%), in comparison to other retrograde cases, where the right coronary artery was most common (70%). The Japanese CTO score was similar between the two groups (3.13 ± 1.23 vs. 3.06 ± 1.06, p = 0.456); however, the IEC group had a higher Prospective Global Registry for the Study of Chronic Total Occlusion Intervention (PROGRESS‐CTO) score (1.95 ± 1.02 vs. 1.27 ± 0.92, p < 0.0001). The most used IEC guidewire was the SUOH 03 (39%), and the most frequently used microcatheter was the Caravel (43%). Dual injection was less common in IEC cases (66% vs. 89%, p < 0.0001). Technical (76% vs. 79%, p = 0.317) and procedural success rates (74% vs. 79%, p = 0.281) were not different between the two groups. However, IEC cases had a higher procedural complications rate (25.8% vs. 16.4%, p = 0.0008), including perforations (17.3% vs. 9.0%, p = 0.0001), pericardiocentesis (3.1% vs. 1.2%, p = 0.018), and dissection/thrombus of the donor vessel (3.7% vs. 1.2%, p = 0.002).ConclusionThe use of IEC for retrograde CTO PCI was associated with similar technical and procedural success rates when compared with other retrograde cases, but higher incidence of periprocedural complications.