Automated asthma detection in a 1326-subject cohort using a one-dimensional attractive-and-repulsive center-symmetric local binary pattern technique with cough sounds

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

AbstractAsthma is a common disease. The clinical diagnosis is usually confirmed on a pulmonary function test, which is not always readily accessible. We aimed to develop a computationally lightweight handcrafted machine learning model for asthma detection based on cough sounds recorded using mobile phones. Toward this aim, we proposed a novel feature extractor based on a one-dimensional version of the published attractive-and-repulsive center-symmetric local binary pattern (1D-ARCSLBP), which we tested on a new cough sound dataset. We prospectively recorded cough sounds from 511 asthmatics and 815 non-asthmatic subjects (comprising mostly healthy volunteers), which yielded 1875 one-second cough sound segments for analysis. Our model comprised four steps: (i) preprocessing, in which speech signals and stop times (silent zones between coughs) were removed, leaving behind analyzable cough sound segments; (ii) feature extraction, in which tunable q-factor wavelet transformation was used to perform multilevel signal decomposition into wavelet subbands, allowing 1D-ARCSLBP to extract local low- and high-level features; (iii) feature selection, in which neighborhood component analysis was used to select the most discriminative features; and (iv) classification, in which a standard shallow cubic support vector machine was deployed to calculate binary classification results (asthma versus non-asthma) using tenfold and leave-one-subject-out cross-validations. Our model attained 98.24% and 96.91% accuracy rates with tenfold and leave-one-subject-out cross-validation strategies, respectively, and obtained a low-time complexity. The excellent results confirmed the feature extraction capability of 1D-ARCSLBP and the feasibility of the model being developed into a real-world application for asthma screening.