Developing and Evaluating the Operating Region of a Grid-Connected Current Source Inverter from Its Mathematical Model

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Grid-connected power inverters are indispensable in modern electrical systems, playing a pivotal role in enhancing the integration of renewable energies into power grids. Their significance, primarily when functioning as grid-forming inverters, extends to maintaining the grid’s inertia and strength—a distinct advancement over traditional grid-following operations. As grid-forming inverters, these devices emulate the characteristics of synchronous generators and can act as robust voltage sources, providing essential ancillary services. This behavior is particularly relevant when integrating energy storage systems on the converters’ direct current side. Among the various inverter topologies, the current source inverter (CSI) has emerged as a promising yet underexplored alternative for grid-forming applications. CSIs, when paired with their AC output filters, can effectively operate as voltage sources, utilizing control strategies that facilitate the integration of renewable energies into the electrical system. Their design inherently manages output current fluctuations, reducing the need for restrictive current limitations or additional protective measures. This paper examines the operational region of CSIs, obtained through detailed modeling, to explore their advantages, challenges, and potential for enhancing grid-connected systems. Analyzing the operating region from the converter model verifies the limits of where the converter can operate in a plane of active and reactive powers. For a small prototype model operating with 7 amperes in DC and 120 V in AC, it is possible to supply or absorb active power exceeding 1000 W and manage maximum reactive power values around 500 VAr, as determined by its operating region. Simulations also confirm that small changes in the control reference, as little as 5%, towards the region’s right limits cause significant oscillations in the dynamic control responses. This research aims to deepen our understanding of CSIs’ operational capabilities and highlight their unique benefits in advancing grid-connected systems and promoting the integration of renewable energy using this technology.