Published in

BMJ Publishing Group, Journal of NeuroInterventional Surgery, p. jnis-2023-020812, 2023

DOI: 10.1136/jnis-2023-020812

Links

Tools

Export citation

Search in Google Scholar

Cerebral emboli detection and autonomous neuromonitoring using robotic transcranial Doppler with artificial intelligence for transcatheter aortic valve replacement with and without embolic protection devices: a pilot study

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

BackgroundPeriprocedural ischemic stroke remains a serious complication in patients undergoing transcatheter aortic valve replacement (TAVR). We used a novel robotic transcranial Doppler (TCD) system equipped with artificial intelligence (AI) for real-time continuous intraoperative neuromonitoring during TAVR to establish the safety and potential validity of this tool in detecting cerebral emboli, report the quantity and distribution of high intensity transient signals (HITS) with and without cerebral protection, and correlate HITS occurrence with various procedural steps.MethodsConsecutive patients undergoing TAVR procedures during which the robotic system was used between October 2021 and May 2022 were prospectively enrolled in this pilot study. The robotic TCD system included autonomous adjustment of the TCD probes and AI-assisted post-processing of HITS and other cerebral flow parameters. Basic demographics and procedural details were recorded. Continuous variables were analyzed by a two-sample Mann–Whitney t-test and categorical variables by a χ2or Fisher test.ResultsThirty-one patients were prospectively enrolled (mean age 79.9±7.6 years; 16 men (51.6%)). Mean aortic valve stenotic area was 0.7 cm2and mean aortic–ventricular gradient was 43 mmHg (IQR 31.5–50 mmHg). Cerebral protection was used in 16 cases (51.6%). Significantly fewer emboli were observed in the protection group than in the non-protection group (mean 470.38 vs 693.33; p=0.01). Emboli counts during valve positioning and implantation were significantly different in the protection and non-protection groups (mean 249.92 and 387.5, respectively; p=0.01). One (4%) transient ischemic attack occurred post-procedurally in the non-protection group.ConclusionWe describe a novel real-time intraoperative neuromonitoring tool used in patients undergoing TAVR. Significantly fewer HITS were detected with protection. Valve positioning–implantation was the most significant stage for intraprocedural HITS.