Published in

Wiley, Acta Anaesthesiologica Scandinavica, 7(67), p. 953-963, 2023

DOI: 10.1111/aas.14253

Links

Tools

Export citation

Search in Google Scholar

Standardized blood volume changes monitored by capnodynamic hemodynamic variables: An experimental comparative study in pigs

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

AbstractBackgroundThe capnodynamic method, based on Volumetric capnography and differential Fick mathematics, assess cardiac output in mechanically ventilated subjects. Capnodynamic and established hemodynamic monitoring parameters' capability to depict alterations in blood volume were investigated in a model of standardized hemorrhage, followed by crystalloid and blood transfusion.MethodsTen anesthetized piglets were subjected to controlled hemorrhage (450 mL), followed by isovolemic crystalloid bolus and blood re‐transfusion. Intravascular blood volume, and all hemodynamic variables, were determined twice after each intervention. The investigated hemodynamic variables were: cardiac output and stroke volume for capnodynamics and pulse contour analysis, respectively, pulse pressure and stroke volume variability and mean arterial pressure. One‐way ANOVA and Tukey's test for multiple comparisons were used to identify significant changes. Trending was assessed by correlation and concordance.ResultConcordance against intravascular volume changes for capnodynamic cardiac output and stroke volume were 96 and 94%, with correlations r = .78 and .68, (p < .0001) with significant changes for 6 and 5 of the 6 measuring points, respectively. Mean arterial pressure and pulse pressure variation had a concordance of 85% and 87%, r = .67 (p < .0001) and r = −.45 (p < .0001), respectively, and both changed significantly for 3 of 6 measuring points. Pulse contour stroke volume variation, stroke volume and cardiac output, showed concordance and correlation of 76%, r = −.18 (p = .11), 63%, r = .28 (p = .01) and 50%, r = .31 (p = .007), respectively and significant change for 1, 1 and 0 of the measuring points, respectively.ConclusionCapnodynamic cardiac output and stroke volume did best depict the changes in intravascular blood volume. Pulse contour parameters did not follow volume changes in a reliable way.