Published in

BMJ Publishing Group, Journal of NeuroInterventional Surgery, p. jnis-2023-020514, 2023

DOI: 10.1136/jnis-2023-020514

Links

Tools

Export citation

Search in Google Scholar

Phenox HPC and Phenox flow modulation devices for the endovascular treatment of intracranial aneurysms: a systematic review and meta-analysis

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

BackgroundSurface-modified flow diverters are increasingly used in clinical settings. However, their safety profiles and additional benefits over non-coated devices still need to be explored. In this meta-analysis, we aimed to investigate and compare the clinical outcomes of the uncoated Phenox and coated Phenox HPC flow diverters.MethodsA systematic literature review was performed using PubMed, Scopus, Embase, and Web of Science databases. Collected data were pooled and corresponding 95% confidence intervals (CI) were calculated. Outcomes of interest included aneurysm occlusion (>6 months) and complication rates. Additionally, the safety outcomes of prophylactic single (SAPT) and dual antiplatelet treatment (DAPT) approaches were compared for patients treated with coated Phenox HPC flow diverters.ResultsWe included 17 studies with 1238 patients. The overall complete occlusion rates were 80% (95% CI 74.01% to 86.56%) for Phenox HPC and 71.3% (95% CI 59.71% to 85.20%) for non-coated Phenox flow diverters (p=0.24). Ischemic complication rates were 7.3% (95% CI 4.6% to 11.39%) with the Phenox HPC and 5.3% (95% CI 4.07% to 6.91%) with the Phenox (p=0.24). For patients treated with Phenox HPC, the SAPT (5.5%; 95% CI 2.83% to 10.85%) and DAPT (7.1%; 95% CI 1.23% to 41.45%) approaches resulted in comparable ischemic complication rates (p=0.79). The DAPT group (4.8%; 95% CI 1.46% to 16.24%) had higher hemorrhagic complication rates than the SAPT group (1.7%; 95% CI 0.52% to 6.09%), but the difference was not statistically significant for patients treated with Phenox HPC (p=0.25).ConclusionsOur findings indicate that Phenox HPC is equally as safe and effective as non-coated Phenox devices. Additionally, our results suggest that prasugrel monotherapy might effectively prevent ischemic complications in patients treated with Phenox HPC flow diverters.