Dissemin is shutting down on January 1st, 2025

Published in

Wiley, Medical Physics, 1(51), p. 224-238, 2023

DOI: 10.1002/mp.16590

Links

Tools

Export citation

Search in Google Scholar

Empirical optimization of energy bin weights for compressing measurements with realistic photon counting x‐ray detectors

Journal article published in 2023 by Yirong Yang, Sen Wang, Debashish Pal, Zhye Yin, Norbert J. Pelc, Adam S. Wang ORCID
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

AbstractBackgroundPhoton counting detectors (PCDs) provide higher spatial resolution, improved contrast‐to‐noise ratio (CNR), and energy discriminating capabilities. However, the greatly increased amount of projection data in photon counting computed tomography (PCCT) systems becomes challenging to transmit through the slip ring, process, and store.PurposeThis study proposes and evaluates an empirical optimization algorithm to obtain optimal energy weights for energy bin data compression. This algorithm is universally applicable to spectral imaging tasks including 2 and 3 material decomposition (MD) tasks and virtual monoenergetic images (VMIs). This method is simple to implement while preserving spectral information for the full range of object thicknesses and is applicable to different PCDs, for example, silicon detectors and CdTe detectors.MethodsWe used realistic detector energy response models to simulate the spectral response of different PCDs and an empirical calibration method to fit a semi‐empirical forward model for each PCD. We numerically optimized the optimal energy weights by minimizing the average relative Cramér–Rao lower bound (CRLB) due to the energy‐weighted bin compression, for MD and VMI tasks over a range of material area density (0–40 g/cm2 water, 0–2.16 g/cm2 calcium). We used Monte Carlo simulation of a step wedge phantom and an anthropomorphic head phantom to evaluate the performance of this energy bin compression method in the projection domain and image domain, respectively.ResultsThe results show that for 2 MD, the energy bin compression method can reduce PCCT data size by 75% and 60%, with an average variance penalty of less than 17% and 3% for silicon and CdTe detectors, respectively. For 3 MD tasks with a K‐edge material (iodine), this method can reduce the data size by 62.5% and 40% with an average variance penalty of less than 12% and 13% for silicon and CdTe detectors, respectively.ConclusionsWe proposed an energy bin compression method that is broadly applicable to different PCCT systems and object sizes, with high data compression ratio and little loss of spectral information.