Dissemin is shutting down on January 1st, 2025

Published in

IOP Publishing, Journal of Radiological Protection, 2(41), p. 360-383, 2021

DOI: 10.1088/1361-6498/abf3b0

Links

Tools

Export citation

Search in Google Scholar

Virtual estimation of effective dose in neutron fields

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract The PODIUM project aims to provide real-time assessments of occupationally exposed workers by tracking their motion and combining this with a simulation of the radiation field. The present work describes the approach that would be taken in mixed neutron-gamma fields, and details the methods for generating and applying an effective dose rate map; the required fluence to effective dose conversion coefficients at intercardinal angles are also presented. A proof-of-concept of the approach is demonstrated using a simple simulated workplace field within a calibration laboratory, with corroborative comparisons made against survey instrument measurements generally confirming good agreement. Simulated tracking of an individual within the facility was performed, recording a 1.25 μSv total effective dose and accounting for dose rates as low as 0.5 nSv h−1, which is much lower than anything that could be accurately measured by physical neutron dosemeters in such a field.