Dissemin is shutting down on January 1st, 2025

Published in

IOP Publishing, Journal of Instrumentation, 03(17), p. P03013, 2022

DOI: 10.1088/1748-0221/17/03/p03013

Links

Tools

Export citation

Search in Google Scholar

Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment

Journal article published in 2022 by C. Ahdida, A. Akmete, R. Albanese, J. Alt, A. Alexandrov, A. Anokhina, S. Aoki, G. Arduini, E. Atkin, N. Azorskiy, J. J. Back, A. Bagulya, F. Baaltasar Dos Santos, A. Baranov, F. Bardou and other authors.
This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract In July 2018 an optimization run for the proposed charm cross section measurement for SHiP was performed at the CERN SPS. A heavy, moving target instrumented with nuclear emulsion films followed by a silicon pixel tracker was installed in front of the Goliath magnet at the H4 proton beam-line. Behind the magnet, scintillating-fibre, drift-tube and RPC detectors were placed. The purpose of this run was to validate the measurement's feasibility, to develop the required analysis tools and fine-tune the detector layout. In this paper, we present the track reconstruction in the pixel tracker and the track matching with the moving emulsion detector. The pixel detector performed as expected and it is shown that, after proper alignment, a vertex matching rate of 87% is achieved.