Published in

MDPI, Diagnostics, 7(12), p. 1551, 2022

DOI: 10.3390/diagnostics12071551

Links

Tools

Export citation

Search in Google Scholar

Individualized Contrast Media Application Based on Body Weight and Contrast Enhancement in Computed Tomography of Livers without Steatosis

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

This study analyzes the homogeneity in liver attenuation of a body-weight-based protocol compared to a semi-fixed protocol. Patients undergoing abdominal multiphase computed tomography received 0.500 g of iodine (gI) per kilogram of body weight. Liver attenuation and enhancement were determined using regions of interest on scans in the pre-contrast and portal venous phases. The outcomes were analyzed for interpatient uniformity in weight groups. The subjective image quality was scored using a four-point Likert scale (excellent, good, moderate, and nondiagnostic). A total of 80 patients were included (56.3% male, 64 years, 78.0 kg) and were compared to 80 propensity-score-matched patients (62.5% male, 63 years, 81.7 kg). The liver attenuation values for different weight groups of the TBW-based protocol were not significantly different (p = 0.331): 109.1 ± 13.8 HU (≤70 kg), 104.6 ± 9.70 HU (70–90 kg), and 105.1 ± 11.6 HU (≥90 kg). For the semi-fixed protocol, there was a significant difference between the weight groups (p < 0.001): 121.1 ± 12.1 HU (≤70 kg), 108.9 ± 11.0 HU (70–90 kg), and 105.0 ± 9.8 HU (≥90 kg). For the TBW-based protocol, the enhancement was not significantly different between the weight groups (p = 0.064): 46.2 ± 15.1 HU (≤70 kg), 59.3 ± 6.8 HU (70–90 kg), and 52.1 ± 11.7 HU (≥90 kg). Additionally, for the semi-fixed protocol, the enhancement was not significantly different between the weight groups (p = 0.069): 59.4 ± 11.0 HU (≤70 kg), 53.0 ± 10.3 HU (70–90 kg), and 52.4 ± 7.5 HU (≥90 kg). The mean administered amount of iodine per kilogram was less for the TBW-based protocol compared to the semi-fixed protocol: 0.499 ± 0.012 and 0.528 ± 0.079, respectively (p = 0.002). Of the TBW-based protocol, 17.5% of the scans scored excellent enhancement quality, 76.3% good, and 6.3% moderate. Of the semi-fixed protocol, 70.0% scored excellent quality, 21.3% scored good, and 8.8% scored moderate. In conclusion, the TBW-based protocol increased the interpatient uniformity of liver attenuation but not the enhancement in the portal venous phase compared to the semi-fixed protocol, using an overall lower amount of contrast media and maintaining good subjective image quality.