Elsevier, The Journal of Thoracic and Cardiovascular Surgery, 2(149), p. 462-470, 2015
DOI: 10.1016/j.jtcvs.2014.10.064
Full text: Download
OBJECTIVES: There remains a paucity of mechanistic data on the effect of transcatheter aortic valve implantation (TAVI) on early left and right ventricular function and quantitative aortic valve regurgitation. We sought to assess and compare the early effects on myocardial function and aortic valve hemodynamics of TAVI and aortic valve replacement (AVR) using serial cardiovascular magnetic resonance (CMR) imaging and echocardiography. METHODS: A prospective comparison study of 47 patients with severe aortic stenosis undergoing either TAVI (n = 26) or high-risk AVR (n = 21). CMR (for left ventricle/right ventricle function, left ventricular mass, left atrial volume, and aortic regurgitation) was carried out before the procedure and early postprocedure (