Published in

IOP Publishing, Journal of Instrumentation, 12(17), p. P12010, 2022

DOI: 10.1088/1748-0221/17/12/p12010

Links

Tools

Export citation

Search in Google Scholar

Operation modes of the KATRIN experiment Tritium Loop System using <sup>83m</sup>Kr

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83mKr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83mKr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83mKr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83mKr-rates, gas densities, and gas compositions inside the WGTS.