Published in

BMJ Publishing Group, BMJ Open, 3(13), p. e065777, 2023

DOI: 10.1136/bmjopen-2022-065777

Links

Tools

Export citation

Search in Google Scholar

Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

IntroductionThere is a worldwide need to enhance the capacity of audiometry testing. The objective of this study is to compare the User-operated Audiometry (UAud) system with traditional audiometry in a clinical setting, by investigating if hearing aid effectiveness based on UAud is non-inferior to hearing aid effectiveness based on traditional audiometry, and whether thresholds obtained with the user-operated version of the Audible Contrast Threshold (ACT) test correlates to traditional measures of speech intelligibility.Methods and analysisThe design will be a blinded non-inferiority randomised controlled trial. 250 adults referred for hearing aid treatment will be enrolled in the study. Study participants will be tested using both traditional audiometry as well as the UAud system and they will answer the questionnaire Speech, Spatial and Qualities of Hearing Scale (SSQ12) at baseline. Participants will be randomly divided to receive hearing aids fitted based on either UAud or traditional audiometry. Three months after participants have started using their hearing aids, they will undergo a hearing in noise test with hearing aids to measure their speech-in-noise performance and answer the following questionnaires: SSQ12, the Abbreviated Profile of Hearing Aid Benefit and the International Outcome Inventory for Hearing Aids. The primary outcome is a comparison of the change in SSQ12 scores from baseline to follow-up between the two groups. Participants will undergo the user-operated ACT test of spectro-temporal modulation sensitivity as part of the UAud system. The ACT results will be compared with measures of speech intelligibility from the traditional audiometry session and follow-up measurements.Ethics and disseminationThe project was evaluated by the Research Ethics Committee of Southern Denmark and judged not to need approval. The findings will be submitted to an international peer-reviewed journal and presented at national and international conferences.Trial registration numberNCT05043207.