Published in

Wiley, Medical Physics, 4(50), p. 2121-2134, 2022

DOI: 10.1002/mp.15893

Links

Tools

Export citation

Search in Google Scholar

Accurate total‐body K<sub>i</sub> parametric imaging with shortened dynamic <sup>18</sup>F‐FDG PET scan durations via effective data processing

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

AbstractBackgroundTotal‐body dynamic positron emission tomography (dPET) imaging using 18F‐fluorodeoxyglucose (18F‐FDG) has received widespread attention in clinical oncology. However, the conventionally required scan duration of approximately 1 h seriously limits the application and promotion of this imaging technique. In this study, we investigated the possibility and feasibility of shortening the total‐body dynamic scan duration to 30 min post‐injection (PI) with the help of a novel Patlak data processing algorithm for accurate Ki estimations of tumor lesions.MethodsTotal‐body dPET images acquired by uEXPLORER (United Imaging Healthcare Inc.) using 18F‐FDG of 15 patients with different tumor types were analyzed in this study. Dynamic images were reconstructed into 25 frames with a specific temporal dividing protocol for the scan data acquired 1 h PI. Patlak analysis‐based Ki parametric imaging was conducted based on the imaging data corresponding to the first 30 min PI, during which a Patlak data processing method based on cubic Hermite interpolation was applied. The resultant Ki images acquired by 30 min dynamic PET data and the standard 1 h Ki images were compared in terms of visual imaging effect, region signal‐to‐noise ratio, and Ki estimation accuracy to evaluate the performance of the proposed Ki imaging method with a shortened scan duration.ResultsWith the help of Patlak data processing, acceptable Ki parametric images were obtained from dynamic PET data acquired with a scan duration of 30 min PI. Compared with Ki images obtained from unprocessed Patlak data, the resulting images from the proposed method performed better in terms of noise reduction. Moreover, Bland–Altman plot and Pearson correlation coefficient analysis showed that that 30 min Ki images obtained from the processed Patlak data had higher accuracy for tumor lesions.ConclusionSatisfactory Ki parametric images with high tumor accuracy can be acquired from dynamic imaging data corresponding to the first 30 min PI. Patlak data processing can help achieve higher Ki imaging quality and higher accuracy regarding tumor lesion Ki values. Clinically, it is possible to shorten the dynamic scan duration of 18F‐FDG PET to 30 min to acquire an accurate tumor Ki and further effective tumor detection with uEXPLORER scanners.