Karger Publishers, Audiology and Neurotology, 6(27), p. 437-448, 2022
DOI: 10.1159/000523969
Full text: Unavailable
<b><i>Introduction:</i></b> Cochlear implant (CI) recipients with normal hearing (NH) in the contralateral ear experience a significant improvement in sound source localization when listening with the CI in combination with their NH-ear (CI + NH) as compared to with the NH-ear alone. The improvement in localization is primarily due to sensitivity to interaural level differences (ILDs). Sensitivity to interaural timing differences (ITDs) may be limited by auditory aging, frequency-to-place mismatches, the signal coding strategy, and duration of CI use. The present report assessed the sensitivity of ILD and ITD cues in CI + NH listeners who were recipients of long electrode arrays that provide minimal frequency-to-place mismatches and were mapped with a coding strategy that presents fine structure cues on apical channels. <b><i>Methods:</i></b> Sensitivity to ILDs and ITDs for localization was assessed using broadband noise (BBN), as well as high-pass (HP) and low-pass (LP) filtered noise for adult CI + NH listeners. Stimuli were 200-ms noise bursts presented from 11 speakers spaced evenly over an 180° arc. Performance was quantified in root-mean-squared error and response patterns were analyzed to evaluate the consistency, accuracy, and side bias of the responses. Fifteen listeners completed the task at the 2-year post-activation visit; seven listeners repeated the task at a later annual visit. <b><i>Results:</i></b> Performance at the 2-year visit was best with the BBN and HP stimuli and poorer with the LP stimulus. Responses to the BBN and HP stimuli were significantly correlated, consistent with the idea that CI + NH listeners primarily use ILD cues for localization. For the LP stimulus, some listeners responded consistently and accurately and with limited side bias, which may indicate sensitivity to ITD cues. Two of the 7 listeners who repeated the task at a later annual visit experienced a significant improvement in performance with the LP stimulus, which may indicate that sensitivity to ITD cues may improve with long-term CI use. <b><i>Conclusions:</i></b> CI recipients with a NH-ear primarily use ILD cues for sound source localization, though some may use ITD cues as well. Sensitivity to ITD cues may improve with long-term CI listening experience.