Dissemin is shutting down on January 1st, 2025

Published in

BMJ Publishing Group, Journal of NeuroInterventional Surgery, 5(15), p. 465-472, 2022

DOI: 10.1136/neurintsurg-2022-018686

Links

Tools

Export citation

Search in Google Scholar

Human “live cadaver” neurovascular model for proximal and distal mechanical thrombectomy in stroke

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

BackgroundPreclinical testing platforms that accurately replicate complex human cerebral vasculature are critical to advance neurointerventional knowledge, tools, and techniques. Here, we introduced and validated a human “live cadaveric” head-and-neck neurovascular model optimized for proximal and distal vascular occlusion and recanalization techniques.MethodsHuman cadaveric head-and-neck specimens were cannulated bilaterally in the jugular veins, carotid, and vertebral arteries. Specimens were then coupled with modular glass models of the aorta and extracranial carotid arteries, as well as radial and femoral access ports. Intracranial physiological flow was simulated using a flow-delivery system and blood-mimicking fluid. Baseline anatomy, histological, and mechanical properties of cerebral arteries were compared with those of fresh specimens. Radiopaque clot analogs were embolized to replicate proximal and distal arterial occlusions, followed by thrombectomy. Experienced interventionalists scored the model on different aspects.ResultsCompared with counterpart fresh human arteries, formalin-fixed arteries showed similar mechanical properties, including maximum stretch, increased tensile strength/stiffness, and friction coefficients were also not significantly different. On histology, minimal endothelial damage was noted in arteries after 3 months of light fixation, otherwise the arterial wall maintained the structural integrity. Contrast angiographies showed no micro- or macro-vasculature obstruction. Proximal and distal occlusions created within the middle cerebral arteries were consistently obtained and successfully recanalized. Additionally, interventionists scored the model highly realistic, indicating great similarity to patients’ vasculature.ConclusionsThe human “live cadaveric” neurovascular model accurately replicates the anatomy, mechanics, and hemodynamics of cerebral vasculature and allows the performance of neurointerventional procedures equivalent to those done in patients.