Evaluation of an ultrasensitive HRP2–based rapid diagnostic test for detection of asymptomatic Plasmodium falciparum parasitaemia among children in western Kenya

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Abstract Background Accurate detection of asymptomatic malaria parasitaemia in children living in high transmission areas is important for malaria control and reduction programmes that employ screen-and-treat surveillance strategies. Relative to microscopy and conventional rapid diagnostic tests (RDTs), ultrasensitive RDTs (us-RDTs) have demonstrated reduced limits of detection with increased sensitivity to detect parasitaemia in symptomatic individuals. In this study, the performance of the NxTek Eliminate Malaria P.f test was compared with traditional microscopy and quantitative polymerase chain reaction (qPCR) testing methods of detection for P. falciparum parasitaemia among asymptomatic children aged 7–14 years living in an area of high malaria transmission intensity in western Kenya. Methods In October 2020, 240 healthy children without any reported malaria symptoms were screened for the presence of P. falciparum parasitaemia; 120 children were randomly selected to participate in a follow-up visit at 6–10 weeks. Malaria parasitaemia was assessed by blood-smear microscopy, us-RDT, and qPCR of a conserved var gene sequence from genomic DNA extracted from dried blood spots. Sensitivity, specificity, and predictive values were calculated for field diagnostic methods using qPCR as the gold standard. Comparison of detectable parasite density distributions and area under the curve were also calculated to determine the effectiveness of the us-RDT in detecting asymptomatic infections with low parasite densities. Results The us-RDT detected significantly more asymptomatic P. falciparum infections than microscopy (42.5% vs. 32.2%, P = 0.002). The positive predictive value was higher for microscopy (92.2%) than for us-RDT (82.4%). However, false negative rates were high for microscopy and us-RDT, with negative predictive values of 53.7% and 54.6%, respectively. While us-RDT detected significantly more infections than microscopy overall, the density distribution of detectable infections did not differ (P = 0.21), and qPCR detected significantly more low-density infections than both field methods (P < 0.001, for both comparisons). Conclusions Us-RDT is more sensitive than microscopy for detecting asymptomatic malaria parasitaemia in children. Though the detectable parasite density distributions by us-RDT in our specific study did not significantly differ from microscopy, the additional sensitivity of the us-RDT resulted in more identified asymptomatic infections in this important group of the population and makes the use of the us-RDT advisable compared to other currently available malaria field detection methods.