In-Situ 5g Nr Base Station Exposure of the General Public: Comparison of Assessment Methods

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract New measurement methods and equipment for correct 5G New Radio (NR) electromagnetic field (EMF) in-situ exposure assessment of instantaneous time-averaged exposure (Eavg) and maximum extrapolated field exposure (Emax) are proposed. The different options are investigated with in-situ measurements around 5G NR base stations (FR1) in different countries. The maximum electric field values satisfy the ICNIRP 2020 limit (maximum 7.7%). The difference between Emax and Eavg is <3 dB for the different measurement equipment at multiple sites in case there is only self-generated traffic. However, in a more realistic scenario, Eavg cannot be used to assess the exposure correctly due to influence of other users as the spatial distribution of user equipment (UE) influences Eavg, while Emax is not affected. However, when multiple UEs are collocated, there is no influence of the number of UEs. A broadband measurement can give a first impression of the RF-EMF exposure up to 700 m, but is not enough to assess the 5G-NR exposure.