Dissemin is shutting down on January 1st, 2025

Published in

American Heart Association, Circulation: Cardiovascular Imaging, 11(14), 2021

DOI: 10.1161/circimaging.121.012809

Links

Tools

Export citation

Search in Google Scholar

Clinical Value of Stress Transaortic Flow Rate During Dobutamine Echocardiography in Reduced Left Ventricular Ejection Fraction, Low-Gradient Aortic Stenosis: A Multicenter Study

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Background: Low rest transaortic flow rate (FR) has been shown previously to predict mortality in low-gradient aortic stenosis. However limited prognostic data exists on stress FR during low-dose dobutamine stress echocardiography. We aimed to assess the value of stress FR for the detection of aortic valve stenosis (AS) severity and the prediction of mortality. Methods: This is a multicenter cohort study of patients with reduced left ventricular ejection fraction and low-gradient aortic stenosis (aortic valve area <1 cm 2 and mean gradient <40 mm Hg) who underwent low-dose dobutamine stress echocardiography to identify the AS severity and presence of flow reserve. The outcome assessed was all-cause mortality. Results: Of the 287 patients (mean age, 75±10 years; males, 71%; left ventricular ejection fraction, 31±10%) over a mean follow-up of 24±30 months there were 127 (44.3%) deaths and 147 (51.2%) patients underwent aortic valve intervention. Higher stress FR was independently associated with reduced risk of mortality (hazard ratio, 0.97 [95% CI, 0.94–0.99]; P =0.01) after adjusting for age, chronic kidney disease, heart failure symptoms, aortic valve intervention, and rest left ventricular ejection fraction. The minimum cutoff for prediction of mortality was stress FR 210 mL/s. Following adjustment to the same important clinical and echocardiographic parameters, among the three criteria of AS severity during stress, ie, the guideline definition of aortic valve area <1cm 2 and aortic valve mean gradient ≥40 mm Hg, or aortic valve mean gradient ≥40 mm Hg, or the novel definition of aortic valve area <1 cm 2 at stress FR ≥210 mL/s, only the latter was independently associated with mortality (hazard ratio, 1.72 [95% CI, 1.05–2.82]; P =0.03). Furthermore aortic valve area <1cm 2 at stress FR ≥210 mL/s was the only severe aortic stenosis criterion that was associated with improved outcome following aortic valve intervention ( P <0.001). Guideline-defined stroke volume flow reserve did not predict mortality. Conclusions: Stress FR during low-dose dobutamine stress echocardiography was useful for the detection of both AS severity and flow reserve and was associated with improved prediction of outcome following aortic valve intervention.