Published in

Public Library of Science, PLoS ONE, 2(17), p. e0262959, 2022

DOI: 10.1371/journal.pone.0262959

Links

Tools

Export citation

Search in Google Scholar

Variation in regional implantation patterns of cardiac implantable electronic device in Switzerland

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Introduction There is a substantial geographical variation in the rates of pacemaker (PM), implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy (CRT) device implantation across European countries. We assessed the extent of regional variation and potential determinants of such variation. Methods We conducted a population-based analysis using discharge data for PM/ICD/CRT implantations from all Swiss acute care hospitals during 2013–2016. We derived hospital service areas (HSA) by analyzing patient flows. We calculated age- and sex-standardized rates and quantified variation using the extremal quotient (EQ) and the systemic component of variation (SCV). We estimated the reduction in variance of crude implantation rates across HSAs using multilevel regression models, with incremental adjustment for age and sex, language, socioeconomic factors, population health, diabetes mellitus, and the density of cardiologists on the HSA level. Results We analyzed implantations of 8129 PM, 1461 ICD, and 1411 CRT from 25 Swiss HSAs. The mean age- and sex-standardized implantation rate was 29 (range 8–57) per 100,000 persons for PM, 5 (1–9) for ICD, and 5 (2–8) for CRT. There was a very high variation in PM (EQ 7.0; SCV 12.6) and ICD (EQ 7.2; SCV 11.3) and a high variation in CRT implantation rates (EQ 3.9; SCV 7.1) across HSAs. Adjustments for age and sex, language, socioeconomic factors, population health, diabetes mellitus, and density of cardiologists explained 94% of the variance in ICD and 87.5% of the variance in CRT implantation rates, but only 36.3% of the variance in PM implantation rates. Women had substantially lower PM/ICD/CRT implantation rates than men. Conclusion Switzerland has a very high regional variation in PM/ICD implantation and a high variation in CRT implantation rates. Women had substantially lower implantation rates than men. A large share of the variation in PM procedure rates remained unexplained which might reflect variations in physicians’ preferences and practices.