Published in

BMJ Publishing Group, BMJ Open, 1(13), p. e068124, 2023

DOI: 10.1136/bmjopen-2022-068124

Links

Tools

Export citation

Search in Google Scholar

Differences in patient characteristics, clinical practice and outcomes of cardiac implantable electric device therapy between Japan and the USA: a cross-sectional study using data from nationally representative administrative databases

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

ObjectivesTo identify differences in patient characteristics, clinical practice and outcomes of cardiac implantable electronic device (CIED) therapy between Japan and the USA.DesignA cross-sectional study.SettingNationally representative administrative databases from Japan and the USA containing hospitalisations with first-time implantations of pacemakers, implantable cardioverter-defibrillators (ICD) and cardiac-resynchronisation therapy with or without defibrillators (CRTP/CRTD).ParticipantsPatients hospitalised with first-time implantations of CIEDs.Outcome measuresIn-hospital mortality, in-hospital complication and 30-day readmission rates.ResultsOverall, 107 339 (median age 78 (71–84), 48 415 women) and 295 584 (age 76 (67–83), 127 349 women) records with CIED implantations were included from Japan and the USA, respectively. Proportion of women in defibrillator recipients was lower in Japan than in the USA (ICD, 21% vs 28%, p<0.001; CRTD, 24% vs 29%, p<0.001). Length of stay after CIED implantation was longer in Japan than in the USA for all device types (conventional pacemaker, 8(7–11) vs 1 (1–3) days, p<0.001; leadless pacemaker, 5 (3–9) vs 2 (1–5) days, p<0.001; ICD, 8 (7–11) vs 1 (1–3) days, p<0.001, CRTP, 9 (7–13) vs 2 (1–4) days, p<0.001; CRTD, 9 (8–14) vs 2 (1–4) days, p<0.001). In-hospital mortality after CIED implantation was similar between Japan and the USA ((OR) (95% CI), conventional pacemaker 0.58 (0.83 to 1.004); ICD 0.77 (0.57 to 1.03); CRTP 0.85 (0.51 to 1.44); CRTD 1.11 (0.81 to 1.51)), except that after leadless pacemaker implantation in Japan was lower than that in the USA (0.32 (0.23 to 0.43)). 30-day readmission rates were lower in Japan than in the USA for all device types (conventional pacemaker 0.55 (0.53 to 0.57); leadless pacemaker 0.50 (0.43 to 0.58); ICD 0.54 (0.49 to 0.58); CRTP 0.51 (0.42 to 0.62); CRTD 0.57 (0.51 to 0.64)).ConclusionsInternational variations in patient characteristics, practice and outcomes were observed. In-hospital mortality after CIED implantation was similar between Japan and the USA, except in cases of leadless pacemaker recipients.