Published in

SAGE Publications, Journal of Endovascular Therapy, 4(28), p. 549-554, 2021

DOI: 10.1177/15266028211010455

Links

Tools

Export citation

Search in Google Scholar

Performance of the Gore VBX Balloon Expandable Endoprosthesis as Bridging Stent-Graft in Branched Endovascular Aortic Repair for Thoracoabdominal Aneurysms

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Purpose Bridging stent stability is crucial for efficacy and safety of branched aortic endovascular repair (bEVAR) of thoracoabdominal aortic aneurysms (TAAAs). In this study, we assess the performance of the new Viabahn Balloon-Expandable endoprosthesis (VBX) in bEVAR. Based on our learning curve we give recommendations for a safe and effective use of the device. Materials and Methods We prospectively collected the data of patients with TAAAs undergoing bEVAR between December 2017 and December 2019. All patients with implantation of at least 1 VBX stent-graft as bridging stent were included in our single-center analysis. Demographic, comorbidity, and computed tomography angiography (CTA) data of 112 patients were retrospectively evaluated. Primary endpoint was a composite of branch-related technical success and freedom from target vessel instability. Secondary endpoints were clinical and ongoing clinical success. Results Primary endpoint: technical success was achieved in all patients (100%) with a freedom from target vessel instability of 96.3% after a median follow-up of 18 months. Overall mortality was 13.4% (n=15) and 13 patients underwent secondary interventions, 12 of them are still alive and 1 suffered from aneurysm sac expansion, consequently an ongoing clinical success of 75.9% was reached. After modification of the implantation technique during the course of the study by selecting longer stent lengths after accurate estimation of vessel curvature and expected adaptation of the flexible endoskeleton to the specific anatomical conditions, no type Ic endoleaks were observed in the last 70 cases. Conclusions The VBX stent-graft can be safely used as bridging stent for branched thoracoabdominal repair. However, learning curve should be considered to avoid type Ic endoleak and edge stenosis. Based on this experience longer landing zones and 2-step deployment of VBX are useful for successful bridging also of challenging target vessels.