Published in

American Academy of Neurology (AAN), Neurology, 16(98), p. e1648-e1659, 2022

DOI: 10.1212/wnl.0000000000200110

Links

Tools

Export citation

Search in Google Scholar

Autopsy Validation of the Diagnostic Accuracy of <sup>123</sup> I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Background and Objectives123I-meta-iodobenzyl-guanidine (123I-MIBG) myocardial scintigraphy is used as a diagnostic imaging test to differentiate Lewy body diseases (LBDs), including Parkinson disease and dementia with Lewy bodies, from other similar diseases. However, this imaging test lacks validation of its diagnostic accuracy against the gold standard. Our aim was to validate the diagnostic accuracy of123I-MIBG myocardial scintigraphy for LBD against autopsy, the gold standard.MethodsThis retrospective, cross-sectional study included consecutive autopsy patients from the Brain Bank for Aging Research who had undergone123I-MIBG myocardial scintigraphy. We compared the123I-MIBG myocardial scintigraphy findings with autopsy findings. Furthermore, the proportion of residual tyrosine hydroxylase (TH)–immunoreactive sympathetic fibers in the anterior wall of the left ventricle was investigated to assess the condition of the cardiac sympathetic nerves assumed to cause reduced123I-MIBG uptake in LBDs.ResultsWe analyzed the data of 56 patients (30 with pathologically confirmed LBDs and 26 without LBD pathology). Compared with the neuropathologic diagnosis, the early heart-to-mediastinum (H/M) ratio had a sensitivity and specificity of 70.0% (95% CI 50.6%–85.3%) and 96.2% (95% CI 80.4%–99.9%), respectively. The delayed H/M ratio had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 92.3% (95% CI 74.9%–99.1%), respectively. The washout rate had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 84.6% (95% CI 65.1%–95.6%), respectively. The proportion of residual TH-immunoreactive cardiac sympathetic fibers strongly correlated with the amount of cardiac123I-MIBG uptake when assessed with early and delayed H/M ratio values (correlation coefficient 0.75 and 0.81, respectively;p< 0.001).DiscussionThis clinicopathologic validation study revealed that123I-MIBG myocardial scintigraphy could robustly differentiate LBDs from similar diseases. Abnormal123I-MIBG myocardial scintigraphy findings strongly support the presence of LBD and cardiac sympathetic denervation. However, LBD pathology should not necessarily be excluded by normal myocardial scintigraphy results, especially when other biomarkers suggest the presence of comorbid Alzheimer disease pathology.Classification of EvidenceThis study provides Class II evidence that123I-MIBG myocardial scintigraphy accurately identifies patients with LBD.