Dissemin is shutting down on January 1st, 2025

Published in

Oxford University Press (OUP), The Journal of Clinical Endocrinology & Metabolism, 11(106), p. e4487-e4496, 2021

DOI: 10.1210/clinem/dgab464

Links

Tools

Export citation

Search in Google Scholar

Second-tier Testing for 21-Hydroxylase Deficiency in the Netherlands: A Newborn Screening Pilot Study

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract Context Newborn screening (NBS) for classic congenital adrenal hyperplasia (CAH) consists of 17-hydroxyprogesterone (17-OHP) measurement with gestational age–adjusted cutoffs. A second heel puncture (HP) is performed in newborns with inconclusive results to reduce false positives. Objective We assessed the accuracy and turnaround time of the current CAH NBS algorithm in comparison with alternative algorithms by performing a second-tier 21-deoxycortisol (21-DF) pilot study. Methods Dried blood spots (DBS) of newborns with inconclusive and positive 17-OHP (immunoassay) first HP results were sent from regional NBS laboratories to the Amsterdam UMC Endocrine Laboratory. In 2017-2019, 21-DF concentrations were analyzed by LC-MS/MS in parallel with routine NBS. Diagnoses were confirmed by mutation analysis. Results A total of 328 DBS were analyzed; 37 newborns had confirmed classic CAH, 33 were false-positive and 258 were categorized as negative in the second HP following the current algorithm. With second-tier testing, all 37 confirmed CAH had elevated 21-DF, while all 33 false positives and 253/258 second-HP negatives had undetectable 21-DF. The elevated 21-DF of the other 5 newborns may be NBS false negatives or second-tier false positives. Adding the second-tier results to inconclusive first HPs reduced the number of false positives to 11 and prevented all 286 second HPs. Adding the second tier to both positive and inconclusive first HPs eliminated all false positives but delayed referral for 31 CAH patients (1-4 days). Conclusion Application of the second-tier 21-DF measurement to inconclusive first HPs improved our CAH NBS by reducing false positives, abolishing the second HP, and thereby shortening referral time.