Published in

BMJ Publishing Group, BMJ Open, 2(11), p. e042735, 2021

DOI: 10.1136/bmjopen-2020-042735

Links

Tools

Export citation

Search in Google Scholar

Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

ObjectiveTo determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward.DesignObservational cohort study.SettingTertiary teaching hospital.ParticipantsPostoperative abdominal surgical patients (n=30) and nurses (n=23).InterventionsPatients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses.OutcomesSystem fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires.ResultsThirty patients were monitored for a median duration of 81 hours (IQR 47–143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1–4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2–4.8) and satisfaction 3.7 (IQR 3.2–4.8), but agreed on ease of learning at 5.0 (IQR 4.0–5.8). Neutral scores were mostly related to the perceived limited fidelity of the system.ConclusionsContinuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses’ ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.