Development of phantom materials with independently adjustable CT- and MR-contrast at 0.35, 1.5 and 3 T

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract Quality assurance in magnetic resonance (MR)-guided radiotherapy lacks anthropomorphic phantoms that represent tissue-equivalent imaging contrast in both computed tomography (CT) and MR imaging. In this study, we developed phantom materials with individually adjustable CT value as well as T 1 - and T 2 -relaxation times in MR imaging at three different magnetic field strengths. Additionally, their experimental stopping power ratio (SPR) for carbon ions was compared with predictions based on single- and dual-energy CT. Ni-DTPA doped agarose gels were used for individual adjustment of T 1 and T 2 at 0.35 , 1.5 and 3.0 T. The CT value was varied by adding potassium chloride (KCl). By multiple linear regression, equations for the determination of agarose, Ni-DTPA and KCl concentrations for given T 1 , T 2 and CT values were derived and employed to produce nine specific soft tissue samples. Experimental T 1 , T 2 and CT values of these soft tissue samples were compared with predictions and additionally, carbon ion SPR obtained by range measurements were compared with predictions based on single- and dual-energy CT. The measured CT value, T 1 and T 2 of the produced soft tissue samples agreed very well with predictions based on the derived equations with mean deviations of less than 3.5 % . While single-energy CT overestimates the measured SPR of the soft tissue samples, the dual-energy CT-based predictions showed a mean SPR deviation of only 0.2 ± 0.3 % . To conclude, anthropomorphic phantom materials with independently adjustable CT values as well as T 1 and T 2 relaxation times at three different magnetic field strengths were developed. The derived equations describe the material specific relaxation times and the CT value in dependence on agarose, Ni-DTPA and KCl concentrations as well as the chemical composition of the materials based on given T 1 , T 2 and CT value. Dual-energy CT allows accurate prediction of the carbon ion range in these materials.