Published in

Newlands Press, Bioanalysis, 22(12), p. 1635-1646, 2020

DOI: 10.4155/bio-2020-0224

Links

Tools

Export citation

Search in Google Scholar

Application of LC–MS/MS method for determination of dihydroartemisin in human plasma in a pharmacokinetic study

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Aim: Dihydroartemisinin (DHA) was also found therapeutic potential for the treatment of systemic lupus erythematosus (SLE). To assess the pharmacokinetic profile of DHA, the concentration of DHA in plasma of SLE patients needed be accurately determined based on a rapid and reliable analytical method. Experimental method & results: Developed method utilizes stable isotope-labeled internal standards and SPE method for sample preparation, applied XBridge C18 column (2.1 × 50 mm, 3.5 μm) for chromatography separation. Detection of the analytes was achieved by an AB Sciex 4000 mass spectrometer under positive electrospray ionization mode. The method was validated in accordance with international guidelines on bioanalytical methods validations. Conclusion: DHA concentrations in human plasma of Chinese SLE patients were quantified by developed LC–MS/MS (no. 2016L02562).