Nature Research, Scientific Reports, 1(10), 2020
DOI: 10.1038/s41598-020-74839-7
Full text: Download
AbstractHypothermic oxygenated machine perfusion (HOPE) was recently tested in preclinical trials in kidney transplantation (KT). Here we investigate the effects of HOPE on extended-criteria-donation (ECD) kidney allografts (KA). Fifteen ECD-KA were submitted to 152 ± 92 min of end-ischemic HOPE and were compared to a matched group undergoing conventional-cold-storage (CCS) KT (n = 30). Primary (delayed graft function-DGF) and secondary (e.g. postoperative complications, perfusion parameters) endpoints were analyzed within 6-months follow-up. There was no difference in the development of DGF between the HOPE and CCS groups (53% vs. 33%, respectively; p = 0.197). Serum urea was lower following HOPE compared to CCS (p = 0.003), whereas the CCS group displayed lower serum creatinine and higher eGFR rates on postoperative days (POD) 7 and 14. The relative decrease of renal vascular resistance (RR) following HOPE showed a significant inverse association with serum creatinine on POD1 (r = − 0.682; p = 0.006) as well as with serum urea and eGFR. Besides, the relative RR decrease was more prominent in KA with primary function when compared to KA with DGF (p = 0.013). Here we provide clinical evidence on HOPE in ECD-KT after brain death donation. Relative RR may be a useful predictive marker for KA function. Further validation in randomized controlled trials is warranted.Trial registration: clinicaltrials.gov (NCT03378817, Date of first registration: 20/12/2017).