Abstract

Abstract OBJECTIVES The aim of this study was to evaluate the proportion of thoraco-abdominal aortic aneurysms (TAAAs) that could theoretically be treated with the JOTEC® E-nside® Thoracoabdominal Branch Endoprosthesis off-the-shelf multibranched endograft. METHODS Preoperative computed tomography scans of patients with atherosclerotic TAAA treated between 2007 and 2019 were reviewed, and the anatomical feasibility of the E-nside graft was verified by a retrospective study (clinicaltrials.gov: NCT03959670) based on the investigational manufacturer instructions for use. The anatomical factors determining overall feasibility were divided into vascular access (AC) feasibility, aortic (AO) feasibility and visceral vessels (VV) feasibility. RESULTS Two hundred sixty-eight patients with thoraco-abdominal aneurysms were analysed: the overall treatment feasibility was 43%. AC feasibility was 78%, AO feasibility 60% and VV feasibility 79%. An iliac diameter <8.5 mm excluded 21% of the patients. Aortic feasibility was limited by infrarenal aortic diameter (16%) and size of aortic lumen at the level of visceral vessels (14%). Visceral vessels feasibility was mainly limited by inadequate number (8%) or diameter (12%) of target vessels. Height and orientation of target vessels were adequate in 97% of the cases. Overall feasibility was negatively influenced by female gender (Odds ratio: 3.89; 95% confidence interval 2.03–7.44; P < 0.001): the limiting factors in this subgroup being iliac diameter, infrarenal aortic diameter and visceral vessels diameter. CONCLUSIONS The E-nside off-the-shelf stent graft can be theoretically employed in almost half of the cases from an all-comers cohort of patients with TAAA. Improvement of device profile and creation of a dedicated infrarenal component are warranted to increase overall feasibility. Female gender significantly affects the overall feasibility. Clinicaltrials.gov NCT03959670.