Dissemin is shutting down on January 1st, 2025

Published in

Oxford University Press, Journal of Analytical Toxicology, 7(45), p. 701-712, 2020

DOI: 10.1093/jat/bkaa131

Links

Tools

Export citation

Search in Google Scholar

A Comprehensive Multi-Analyte Method for Hair Analysis: Substance-Specific Quantification Ranges and Tool for Task-Oriented Data Evaluation

Journal article published in 2020 by C. Scholz, J. Cabalzar, T. Kraemer ORCID, M. R. Baumgartner
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract The aim of the present study was to quantify a large number of analytes including opioids, stimulants, benzodiazepines, z-drugs, antidepressants and neuroleptics within a single sample workup followed by a single analytical measurement. Expected drug concentrations in hair are strongly substance dependent. Therefore, three different calibration ranges were implemented: 0.5 to 600 pg/mg (group 1), 10 to 12,000 pg/mg (group 2) and 50 to 60,000 pg/mg (group 3). In order to avoid saturation effects, different strategies were applied for selected transitions including the use of parent mass ions containing one or two 13C-isotopes and detuning of the declustering potential and/or collision energy. Drugs were extracted from pulverized hair by a two-step extraction protocol and measured by liquid chromatrography--tandem mass spectrometry (LC--MS-MS) using Scheduled MRM™ Algorithm Pro. In total, 275 MRM transitions including 43 deuterated standards were measured. The method has been fully validated according to international guidelines. A MultiQuant™ software based tool for task-oriented data evaluation was established, which allows extracting selected information from the measured data sets. The matrix effects and recoveries were within the allowed ranges for the majority of the analytes. The lower limits of quantification (LLOQs) were for ∼72% of the analytes in the low-pg/mg range (0.5–5 pg/mg) and for ∼24% of the analytes between 10 and 50 pg/mg. These LLOQs considered cut-offs by the Society of Hair Testing (SoHT), if recommended. The herein established multi-analyte approach meets the specific requirements of forensic hair testing and can be used for the rapid and robust measurement of a wide range of psychoactive substances. The analyte-specific wide concentration ranges open up a wide field of applications.