Published in

IOP Publishing, Research in Astronomy and Astrophysics, 9(20), p. 153, 2020

DOI: 10.1088/1674-4527/20/9/153

Links

Tools

Export citation

Search in Google Scholar

Calibration and performance of the neutron detector onboard of the DAMPE mission

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract The DArk Matter Particle Explorer (DAMPE), one of the four space-based scientific missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, was successfully launched on 2015 Dec. 17 from Jiuquan launch center. One of the most important scientific goals of DAMPE is to search for evidence of dark matter indirectly by measuring the spectrum of high energy cosmic-ray electrons. The neutron detector, one of the four sub-payloads of DAMPE, is designed to distinguish high energy electrons from hadron background by measuring the secondary neutrons produced in the shower. In this paper, a comprehensive introduction of the neutron detector is presented, including the design, calibration and performance. The analysis with simulated data and flight data indicates a powerful proton rejection capability of the neutron detector, which plays an essential role for TeV electron identification of DAMPE.