Dissemin is shutting down on January 1st, 2025

Published in

European Respiratory Society, European Respiratory Journal, 1(57), p. 2000182, 2020

DOI: 10.1183/13993003.00182-2020

Links

Tools

Export citation

Search in Google Scholar

Automated closed-loop versus standard manual oxygen administration after major abdominal or thoracic surgery: an international multicentre randomised controlled study

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

IntroductionHypoxaemia and hyperoxaemia may occur after surgery, with related complications. This multicentre randomised trial evaluated the impact of automated closed-loop oxygen administration after high-risk abdominal or thoracic surgeries in terms of optimising the oxygen saturation measured by pulse oximetry time within target range.MethodsAfter extubation, patients with an intermediate to high risk of post-operative pulmonary complications were randomised to “standard” or “automated” closed-loop oxygen administration. The primary outcome was the percentage of time within the oxygenation range, during a 3-day frame. The secondary outcomes were the time with hypoxaemia and hyperoxaemia under oxygen.ResultsAmong the 200 patients, time within range was higher in the automated group, both initially (≤3 h; 91.4±13.7% versus 40.2±35.1% of time, difference +51.0% (95% CI −42.8–59.2%); p<0.0001) and during the 3-day period (94.0±11.3% versus 62.1±23.3% of time, difference +31.9% (95% CI 26.3–37.4%); p<0.0001). Periods of hypoxaemia were reduced in the automated group (≤3 days; 32.6±57.8 min (1.2±1.9%) versus 370.5±594.3 min (5.0±11.2%), difference −10.2% (95% CI −13.9–−6.6%); p<0.0001), as well as hyperoxaemia under oxygen (≤3 days; 5.1±10.9 min (4.8±11.2%) versus 177.9±277.2 min (27.0±23.8%), difference −22.0% (95% CI −27.6–−16.4%); p<0.0001). Kaplan–Meier analysis depicted a significant difference in terms of hypoxaemia (p=0.01) and severe hypoxaemia (p=0.0003) occurrence between groups in favour of the automated group. 25 patients experienced hypoxaemia for >10% of the entire monitoring time during the 3 days within the standard group, as compared to the automated group (p<0.0001).ConclusionAutomated closed-loop oxygen administration promotes greater time within the oxygenation target, as compared to standard manual administration, thus reducing the occurrence of hypoxaemia and hyperoxaemia.