Published in

Universidad de Murcia, Enfermería Global, 3(19), p. 36-67, 2020

DOI: 10.6018/eglobal.387451

Links

Tools

Export citation

Search in Google Scholar

Variáveis associadas a eventos adversos em neonatos com cateter central de inserção periférica

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Objetivo: Identificar los factores asociados con la aparición de eventos adversos en el catéter de inserción central periférica en recién nacidos.Métodos: Un estudio transversal con un enfoque cuantitativo realizado en una Unidad de Cuidados Intensivos Neonatales de un hospital de maternidad de referencia en atención materna e infantil de alto riesgo en el noreste de Brasil. Muestra de 108 neonatos recolectados de febrero a noviembre de 2016.Resultados: La prevalencia de eventos adversos en los recién nacidos fue del 53,70%, asociada a las siguientes variables: sexo masculino (p = 0,033), peso inferior a 2500 gramos (p = 0,003), inserción después de 48 horas (p = 0,027), más de tres intentos de punción (p = 0,024), dificultad de progresión del catéter (p = 0,040), presencia de intercurrencias durante la inserción del catéter (p = 0,027), sobre dos cambios de apósito = 0.009) y ubicación no central del dispositivo (p = 0.042).Conclusión: Los resultados indican la necesidad de estrategias para la prevención de eventos adversos, con énfasis en la educación continua y el mejoramiento de habilidades en la gestión de este dispositivo. Objective: To identify the factors associated with the occurrence of adverse events by a peripherally inserted central catheter in newborns. Methods: A quantitative, cross-sectional study carried out in the Neonatal Intensive Care Unit of a reference maternity hospital in high-risk maternal and child care in Northeast Brazil. The sample of 108 neonates was collected from February to November 2016. Results: The prevalence of adverse events in newborns was 53.70%, associated with the following variables: male gender (p=0.033), weight below 2500 grams (p=0.003), insertion performed after 48 hours of life (p=0.027), more than three puncture attempts (p=0.024), difficulty in inserting the catheter (p=0.040), intercurrence during catheter insertion (p=0.027), over two dressing changes (p=0.009), and non-central position of the device (p=0.042). Conclusion: The results indicate the need for strategies to prevent adverse events, with emphasis on continuing education and on the improvement of skills regarding the use of this device.