Robust treatment planning with 4D intensity modulated carbon ion therapy for multiple targets in stage IV non-small cell lung cancer

Journal article published in 2020 by Moritz Ernst Wolf, Kristjan Anderle, Marco Durante ORCID, Christian Graeff ORCID
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract Intensity modulated particle therapy (IMPT) with carbon ions can generate highly conformal treatment plans; however, IMPT is limited in robustness against range and positioning uncertainty. This is particularly true for moving targets, even though all motion states of a 4DCT are considered in 4D-IMPT. Here, we expand 4D-IMPT to include robust non-linear RBE-weighted optimization to explore its potential in improving plan robustness and sparing critical organs. In this study, robust 4D-optimization—based on worst-case optimization on 9 scenarios—was compared to conventional 4D-optimization with PTV margins using 4D dose calculation and robustness analysis for 21 uncertainty scenarios. Slice-by-slice rescanning was used for motion mitigation. Both 4D-optimization strategies were tested on a cohort of 8 multi-lesion lung cancer patients with the goal of prioritizing OAR sparing in a hypofractionated treatment plan. Planning objectives were to keep the OAR volume doses below corresponding limits while simultaneously achieve CTV coverage with D95% ≥ 95 %. For the conventional plans, average D95% was at 98.7% which fulfilled the target objective in 83.2% of scenarios. For the robust plans, average D95% was reduced to 97.6% which still fulfilled the target objective in 80.7% of cases, but led to significantly improved overall OAR sparing: Volume doses were below the limits in 96.2% of cases for the conventional and 99.5% for the robust plans. When considering the particularly critical smaller airways only, fulfillment rates could be increased from 76.2% to 96% for the robust plans. This study has shown that plan robustness of 4D-IMPT could be improved by using robust 4D-optimization, offering greater control over uncertainties in the actual delivered dose. In some cases, this required sacrificing target coverage for the benefit of better OAR sparing.