Transradial Woven EndoBridge device to treat a ruptured basilar tip aneurysm under conscious sedation

Journal article published in 2020 by P. Bhogal ORCID, N. Chan ORCID, Hld Makalanda, K. Wong, J. Noblet
This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Question mark in circle
Preprint: policy unknown
Question mark in circle
Postprint: policy unknown
Question mark in circle
Published version: policy unknown
Data provided by SHERPA/RoMEO

Abstract

We present a patient with a ruptured basilar tip aneurysm treated under conscious sedation via a right radial approach using the Woven EndoBridge device. We discuss the technical aspects of the case as the well as the available literature on the treatment of ruptured aneurysms treated without general anaesthesia. We discuss the potential benefits of the Woven EndoBridge device in such situations.