Published in

Future Medicine, Journal of Comparative Effectiveness Research, 5(9), p. 375-385, 2020

DOI: 10.2217/cer-2019-0156

Links

Tools

Export citation

Search in Google Scholar

Intracardiac echocardiography use and outcomes after catheter ablation of ventricular tachycardia

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Aim: To compare outcomes among patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing outpatient ventricular tachycardia (VT) catheter ablation using intracardiac echocardiography (ICE) versus no ICE. Patients & methods: Patients were classified into ICE (n = 1143)/non-ICE (n = 1677) groups based on ICE procedure codes. Patients in each group were propensity matched on study covariates. Survival analyses were used to assess outcomes. To examine residual confounding, falsification outcomes were evaluated. Results: ICE patients had a 24% lower risk of all-cause readmissions, 24% lower risk of cardiovascular-related and 20% lower risk of VT-related readmissions compared with non-ICE patients. Falsification analyses for ICE use association were nonsignificant. Conclusion: Patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing VT ablation with ICE use had significantly lower likelihood of VT-related readmission.