Published in

BMJ Publishing Group, BMJ Quality & Safety, 11(29), p. 905-911, 2020

DOI: 10.1136/bmjqs-2019-010463

Links

Tools

Export citation

Search in Google Scholar

Appropriateness of peripherally inserted central catheter use among general medical inpatients: an observational study using routinely collected data

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

BackgroundPeripherally inserted central catheters (PICC) are among the most commonly used medical devices in hospital. This study sought to determine the appropriateness of inpatient PICC use in general medicine at five academic hospitals in Toronto, Ontario, Canada, based on the Michigan Appropriateness Guide for Intravenous Catheters (MAGIC).MethodsThis was a retrospective, cross-sectional study of general internal medicine patients discharged between 1 April 2010 and 31 March 2015 who received a PICC during hospitalisation. The primary outcomes were the proportions of appropriate and inappropriate inpatient PICC use based on MAGIC recommendations. Hospital administrative data and electronic clinical data were used to determine appropriateness of each PICC placement. Multivariable regression models were fit to explore patient predictors of inappropriate use.ResultsAmong 3479 PICC placements, 1848 (53%, 95% CI 51% to 55%) were appropriate, 573 (16%, 95% CI 15% to 18%) were inappropriate and 1058 (30%, 95% CI 29% to 32%) were of uncertain appropriateness. The proportion of appropriate and inappropriate PICCs ranged from 44% to 61% (p<0.001) and 13% to 21% (p<0.001) across hospitals, respectively. The most common reasons for inappropriate PICC use were placement in patients with advanced chronic kidney disease (n=500, 14%) and use for fewer than 15 days in patients who are critically ill (n=53), which represented 14% of all PICC placements in the intensive care unit. Patients who were older, female, had a Charlson Comorbidity Index score greater than 0 and more severe illness based on the Laboratory-based Acute Physiology Score were more likely to receive an inappropriate PICC.ConclusionsClinical practice recommendations can be operationalised into measurable domains to estimate the appropriateness of PICC insertions using routinely collected hospital data. Inappropriate PICC use was common and varied substantially across hospitals in this study, suggesting that there are important opportunities to improve care.