Dissemin is shutting down on January 1st, 2025

Published in

BMJ Publishing Group, BMJ Open, 2(10), p. e031128, 2020

DOI: 10.1136/bmjopen-2019-031128

Links

Tools

Export citation

Search in Google Scholar

Availability and use of continuous positive airway pressure (CPAP) for neonatal care in public health facilities in India: a cross-sectional cluster survey

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

ObjectivesTo determine the availability of continuous positive airway pressure (CPAP) and to provide an overview of its use in neonatal units in government hospitals across India.SettingCross-sectional cluster survey of a nationally representative sample of government hospitals from across India.Primary outcomesAvailability of CPAP in neonatal units.Secondary outcomesProportion of hospitals where infrastructure and processes to provide CPAP are available. Case fatality rates and complication rates of neonates treated with CPAP.ResultsAmong 661 of 694 government hospitals with neonatal units that provided information on availability of CPAP for neonatal care, 68.3% of medical college hospitals (MCH) and 36.6% of district hospitals (DH) used CPAP in neonates. Assessment of a representative sample of 142 hospitals (79 MCH and 63 DH) showed that air-oxygen blenders were available in 50.7% (95% CI 41.4% to 60.9%) and staff trained in the use of CPAP were present in 56.0% (45.8% to 65.8%) of hospitals. The nurse to patient ratio was 7.3 (6.4 to 8.5) in MCH and 6.6 (5.5 to 8.3) in DH. Clinical guidelines were available in 31.0% of hospitals (22.2% to 41.4%). Upper oxygen saturation limits of above 94% were used in 72% (59.8% to 81.6%) of MCH and 59.3% (44.6% to 72.5%) of DH. Respiratory circuits were reused in 53.8% (42.3% to 63.9%) of hospitals. Case fatality rate for neonates treated with CPAP was 21.4% (16.6% to 26.2%); complication rates were 0.7% (0.2% to 1.2%) for pneumothorax, 7.4% (0.9% to 13.9%) for retinopathy and 1.4% (0.7% to 2.1%) for bronchopulmonary dysplasia.ConclusionsCPAP is used in neonatal units across government hospitals in India. Neonates may be overexposed to oxygen as the means to detect and treat consequences of oxygen toxicity are insufficient. Neonates may also be exposed to nosocomial infections by reuse of disposables. Case fatality rates for neonates receiving CPAP are high. Complications might be under-reported. Support to infrastructure, training, guidelines implementation and staffing are needed to improve CPAP use.