Springer, Skeletal Radiology, 4(49), p. 549-554, 2019
DOI: 10.1007/s00256-019-03292-z
Full text: Unavailable
Abstract Objective To evaluate organ dose and total effective dose of whole-body low-dose CT (WBLDCT) performed on different CT-scanner models in patients with multiple myeloma (MM) and to compare it to the effective dose of radiographic skeletal survey and representative diagnostic CTs. Material and methods We retrospectively analyzed data from 228 patients (47.4% females, mean age 67.9 ± 10.4 years, mean weight 81.8 ± 22.4 kg) who underwent WBLDCT for the work-up or surveillance of MM. Patients were scanned using one of six multi-detector CT-scanners. Organ doses and total effective doses per scan were calculated using a commercially available dose-management platform (Radimetrics, Bayer Healthcare, Leverkusen, Germany). The median effective dose was compared to radiographic skeletal survey and representative diagnostic CTs. Results The mean effective dose of our WBLDCT-protocol was 4.82 mSv. A significantly higher effective dose was observed in females compared to males (4.95 vs. 4.70 mSv, P = 0.002). Mean organ dose ranged from 3.72 mSv (esophagus) to 13.09 mSv (skeleton). Mean effective dose varied amongst different CT-scanners (range 4.34–8.37 mSv). The median effective dose of WBLDCT was more than twice the dose of a skeletal survey (4.82 vs. 2.04 mSv), 23% higher than a diagnostic contrast-enhanced chest CT (3.9 mSv), 46% lower than a diagnostic contrast-enhanced abdomen/pelvis CT (9.0 mSv), and 45% lower than a lumbar spine CT (8.7 mSv). Conclusions WBLDCT in MM has a higher effective dose than a radiographic skeletal survey, but a lower effective dose than diagnostic CTs of lumbar spine, abdomen and pelvis. This underlines the broad applicability of WBLDCT in the management of MM patients.