Dissemin is shutting down on January 1st, 2025

Published in

British Institute of Radiology, British Journal of Radiology, 1106(93), p. 20180850, 2020

DOI: 10.1259/bjr.20180850

Links

Tools

Export citation

Search in Google Scholar

Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Orange circle
Preprint: archiving restricted
Orange circle
Postprint: archiving restricted
Orange circle
Published version: archiving restricted
Data provided by SHERPA/RoMEO

Abstract

Objective: Determination of the optimal energy level of virtual monochromatic image (VMI) for brain metastases in contrast-enhanced dual-energy CT (DECT) for radiosurgery and assessment of the subjective and objective image quality of VMI at the optimal energy level. Methods: 20 patients (total of 42 metastases) underwent contrast-enhanced DECT. Spectral image analysis of VMIs at energy levels ranging from 40 to 140 keV in 1 keV increments was performed to determine the optimal VMI (VMIopt) as the one corresponding to the highest contrast-to-noise ratio (CNR) between brain parenchyma and the metastases. The objective and subjective values of VMIopt were compared to those of the VMI with 120 kVp equivalent, defined as reference VMI (VMIref, 77 keV). The objective measurement parameters included mean HU value and SD of tumor and brain parenchyma, absolute lesion contrast (LC), and CNR. The subjective measurements included five-point scale assessment of “overall image quality” and “tumor delineation” by three radiation oncologists. Results: The VMI at 63 keV was defined as VMIopt. The LC and CNR of VMIopt were significantly (p < 0.01) higher than those of VMIref (LC: 37.4 HU vs 24.7 HU; CNR: 1.1 vs 0.8, respectively). Subjective analysis rated VMIopt significantly (p < 0.01) superior to VMIref with respect to the overall image quality (3.2 vs 2.9, respectively) and tumor delineation (3.5 vs 2.9, respectively). Conclusion: The VMI at 63 keV derived from contrast-enhanced DECT yielded the highest CNR and improved the objective and subjective image quality for radiosurgery, compared to VMIref. Advances in knowledge: This paper investigated for the first time the optimal energy level of VMI in DECT for brain metastases. The findings will lead to improvement in tumor visibility with optimal VMI and consequently supplement accuracy delineation of brain metastases.