Long-term stability of guided wave electromagnetic acoustic transducer systems

Journal article published in 2018 by Balint Herdovics ORCID, Frederic Cegla ORCID
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

This article evaluates the long-term stability of a Lorentz force guided wave electromagnetic acoustic transducer. The specific application of the investigated electromagnetic acoustic transducer is pipeline health monitoring using low-frequency (27 kHz) long-range torsional guided waves. There is a concern that repeated swings in the temperature of the structure can cause irreversible changes in the transduction mechanism and therefore pose a risk to the long-term stability of transducers. In this article we report on guided wave signals acquired on a custom-built transducer while it was exposed to more than 90 heating cycles. The highest temperature that was reached during cycling was 80°C and the measurements were acquired over a 14-month period. At the end of the 1-year period, the transducer phase had changed by 23.32° and its amplitude by 3.7%. However, this change was not gradual and most of the change occurred early on, before the highest temperature was first reached in the temperature cycling process. The observed change after this was 6.08° phase shift and 0.9% amplitude change. The possible sources of output changes were investigated, and it was found that the mechanical properties of the contact layer between the electromagnetic acoustic transducer and the pipe surface was very important. A soft silicone interlayer performed best and was able to reduce temperature-induced phase changes in the monitored signals from a maximum of 80 degrees phase change to about 20 degrees phase change, a fourfold reduction.