Published in

MDPI, Journal of Clinical Medicine, 12(8), p. 2167, 2019

DOI: 10.3390/jcm8122167

Links

Tools

Export citation

Search in Google Scholar

Bioresorbable Vascular Scaffolds—Dead End or Still a Rough Diamond?

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Percutaneous coronary interventions with stent-based restorations of vessel patency have become the gold standard in the treatment of acute coronary states. Bioresorbable vascular scaffolds (BVS) have been designed to combine the efficiency of drug-eluting stents (DES) at the time of implantation and the advantages of a lack of foreign body afterwards. Complete resolution of the scaffold was intended to enable the restoration of vasomotor function and reduce the risk of device thrombosis. While early reports demonstrated superiority of BVS over DES, larger-scale application and longer observation exposed major concerns about their use, including lower radial strength and higher risk of thrombosis resulting in higher rate of major adverse cardiac events. Further focus on procedural details and research on the second generation of BVS with novel properties did not allow to unequivocally challenge position of DES. Nevertheless, BVS still have a chance to present superiority in distinctive indications. This review presents an outlook on the available first and second generation BVS and a summary of results of clinical trials on their use. It discusses explanations for unfavorable outcomes, proposed enhancement techniques and a potential niche for the use of BVS.