Published in

Clinical Oncology and Research, p. 1-11, 2019

DOI: 10.31487/j.cor.2019.5.17

Links

Tools

Export citation

Search in Google Scholar

Fluorothymidine Positron Emission Tomography (FLT-PET) Repeatability and Response Evaluation in Advanced Pancreatic Cancer Patients Treated with Gemcitabine-Based Chemotherapy

This paper was not found in any repository; the policy of its publisher is unknown or unclear.
This paper was not found in any repository; the policy of its publisher is unknown or unclear.

Full text: Unavailable

Question mark in circle
Preprint: policy unknown
Question mark in circle
Postprint: policy unknown
Question mark in circle
Published version: policy unknown

Abstract

Purpose: This study aimed to evaluate the feasibility and repeatability of [18F]-fluorothymidine positron emission tomography (FLT-PET) and its utility as a proliferative imaging marker to evaluate response in patients with advanced pancreatic adenocarcinoma (PDAC) receiving gemcitabine-based chemotherapy. Methods: PDAC patients due to commence gemcitabine-based chemotherapy underwent FLT-PET over 60 minutes, before (baseline) and after 28 days of chemotherapy. Repeatability was assessed by a second FLT-PET scan within 7 days of baseline scan and before starting chemotherapy. Scans were assessed by two independent physician’s to determine inter-reporter concordance. FLT-PET uptake over 45-60 minutes was estimated as maximum and mean standardised uptake values (SUVmax and SUVmean). Exploratory analysis of tissue biomarkers was performed from archival tissue samples. Results: All 18 of the 21 patients consented who were imaged had primary tumour in-situ and 83% had metastases with 60% in liver. 17 patients received gemcitabine-based treatment. Thirty-five FLT-PET scans were acquired (89% evaluable) and 26 lesions delineated (17 primary tumours, 9 liver metastases). At baseline, liver metastases showed higher uptake compared with primary tumour with mean (SD) SUVmax [7.2 (1.1) vs 4.5 (1.3); p < 0.001] and SUVmean [4.7 (0.6) vs 2.1 (0.6); p < 0.001)]. There was good intra-patient repeatability and inter-reporter concordance with mean (SD) test-retest difference and inter-reporter Lin’s concordance coefficient being 4.9% (17.6) and 0.703 for SUVmax and -5.4% (SD 9.8) and 0.710 for SUVmean, respectively. However, gemcitabine-capecitabine combination therapy resulted in a higher FLT uptake compared to gemcitabine alone, although this did not translate to clinical benefit. No relationship was observed between tissue markers and FLT in half of the subjects imaged whose tissue was available. Conclusions: FLT-PET is a feasible and reproducible imaging technique in patients with PDAC to evaluate proliferation-targeting therapy, using a simplified imaging protocol in well-designed clinical trials.