Published in

MDPI, Energies, 13(12), p. 2537, 2019

DOI: 10.3390/en12132537

Links

Tools

Export citation

Search in Google Scholar

On the Use of Infrared Thermography and Acousto—Ultrasonics NDT Techniques for Ceramic-Coated Sandwich Structures

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Ceramic-coated materials used in different engineering sectors are the focus of world-wide interest and have generated a need for inspection techniques that detect very small structural anomalies. Non-destructive testing is increasingly being used to evaluate coating thickness and to test for coating flaws. The main pros of non-destructive testing is that the tested object remains intact and available for continued use afterward. This paper reports on an integrated, non-destructive testing approach that combines infrared thermography and acousto-ultrasonics to evaluate advanced aerospace sandwich structure materials with the aim of exploring any potential for detecting defects of more than one type. Combined, these two techniques successfully detected fabrication defects, including inclusions and material loss.