Reliability of colour perimetry to assess macular pigment optical density in age-related macular degeneration

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Background: The aim of this study was to determine the intra-session repeatability and inter-examiner reproducibility of the colour perimetry technique when assessing in vivo macular pigment optical density in age-related macular degeneration patients. Methods: Age-related macular degeneration patients were classified into four groups: early age-related macular degeneration, intermediate age-related macular degeneration, atrophic age-related macular degeneration and neovascular age-related macular degeneration after undergoing fundus photography (TRC 50DX type IA) and spectral-domain optical coherence tomography analysis (Topcon 3D-2000). Central fixation was confirmed in all patients using the MP-1 microperimeter (Nidek, Padua, Italy). To analyse repeatability, one examiner obtained three consecutive macular pigment optical density measures with MonCV3 device (Metrovision, Perenchies, France). To study agreement between two observers, a second examiner performed another macular pigment optical density measurement in random order. Within-subject standard deviation, coefficient of variation, and intraclass correlation coefficient data were obtained. Results: Fifty two (32 females and 20 males) consecutive age-related macular degeneration patients having a mean age of 71.5 ± 8.2 years were recruited. Six had early age-related macular degeneration, 25 had intermediate age-related macular degeneration, 10 had atrophic age-related macular degeneration and 11 had neovascular age-related macular degeneration. For repeatability, coefficient of variation values ranged from 22.3% (neovascular age-related macular degeneration) to 41.0% (atrophic age-related macular degeneration) and intraclass correlation coefficient values from 0.52 (intermediate age-related macular degeneration) to 0.79 (neovascular age-related macular degeneration). For agreement between two examiners, coefficient of variation values ranged from 20.1% (intermediate age-related macular degeneration) to 37.8% (neovascular age-related macular degeneration) and intraclass correlation coefficient values from 0.61 (neovascular age-related macular degeneration) to 0.80 (atrophic age-related macular degeneration). Conclusion: The reliability (intra-session repeatability and inter-examiner reproducibility) of colour perimetry technique to assess macular pigment optical density in age-related macular degeneration patients is only moderate. Thus, it cannot be recommended to be performed when evaluating and monitoring age-related macular degeneration patients in the daily clinic.