Used properly, daylight can provide visual comfort, reduce energy consumption and improve health and safety at work. This paper investigates the influence that different roof types, (i.e., sawtooth roof, skylight and monitor), have on daylight levels, along with the construction cost in an industrial environment in Athens, Greece. Construction costs and daylight adequacy/uniformity are antagonistic phenomena, since as the distance between the roof openings increases, the construction cost is minimised, while the daylight levels and the uniformity are reduced. Therefore, an optimisation method is proposed in order to find the optimum distance between the roof openings. The selected building is a representative unit of Greek industrial facilities, while the optimisation method is based upon a multiparametric approach. This consists of three (3) different roof opening arrangement types with different geometric characteristics. The daylight metrics used are the Daylight Area, the Daylight Factor, the Mean Daylight Autonomy, the Uniform Daylight Index and the Annual Sunlight Exposure. Overall, sawtooth roofs represent the best choice for daylight provision in industrial buildings at the examined geographic location. Using the aforementioned optimisation method, the optimum solution of distances between the roof openings ranges from 10 m to 13 m.