Published in

Wiley Open Access, Journal of the American Heart Association, 11(8), 2019

DOI: 10.1161/jaha.119.012707

Links

Tools

Export citation

Search in Google Scholar

Telomere Length and Vascular Phenotypes in a Population‐Based Cohort of Children and Midlife Adults

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Background Telomere length has been inversely associated with cardiovascular disease in adulthood, but its relationship to preclinical cardiovascular phenotypes across the life course remains unclear. We investigated associations of telomere length with vascular structure and function in children and midlife adults. Methods and Results Population‐based cross‐sectional CheckPoint (Child Health CheckPoint) study of 11‐ to 12‐year‐old children and their parents, nested within the LSAC (Longitudinal Study of Australian Children). Telomere length (telomeric genomic DNA [T]/β‐globin single‐copy gene [S] [T/S ratio]) was measured by quantitative polymerase chain reaction from blood‐derived genomic DNA. Vascular structure was assessed by carotid intima‐media thickness, and vascular function was assessed by carotid‐femoral pulse‐wave velocity and carotid elasticity. Mean (SD) T/S ratio was 1.09 (0.55) in children (n=1206; 51% girls) and 0.81 (0.38) in adults (n=1343; 87% women). Linear regression models, adjusted for potential confounders, revealed no evidence of an association between T/S ratio and carotid intima‐media thickness, carotid‐femoral pulse‐wave velocity, or carotid elasticity in children. In adults, longer telomeres were associated with greater carotid elasticity (0.14% per 10–mm Hg higher per unit of T/S ratio; 95% CI, 0.04%–0.2%; P =0.007), but not carotid intima‐media thickness (−0.9 μm; 95% CI, −14 to 13 μm; P =0.9) or carotid‐femoral pulse‐wave velocity (−0.10 m/s; 95% CI, −0.3 to 0.07 m/s; P =0.2). In logistic regression analysis, telomere length did not predict poorer vascular measures at either age. Conclusions In midlife adults, but not children, there was some evidence that telomere length was associated with vascular elasticity but not thickness. Associations between telomere length and cardiovascular phenotypes may become more evident in later life, with advancing pathological changes.